RO Plant Capacity - 5000 LPH


RO Plant Capacity 5000 LPH

  • 5000 LPH SS Plant
  • 5000 LPH MS Plant
  • 5000 LPH SS Skid
Particular SS Plant MS Plant SS Skid
1) Raw Water Pump
Type Self Priming/Centrifugal Self Priming/Centrifugal Self Priming/Centrifugal
Motor 3 HP 3 HP 3 HP
Make Silver / Crompton, equip.. Silver / Crompton, equip.. Silver / Crompton, equip..
Flow Rate 2 m3/h 2 m3/h 2 m3/h
2)Dual Media Filter
Type Down Flow Down Flow Down Flow
M.O.C. SS Size 1672 SS Size 1672 SS Size 1672
Capacity 190 Ltr 190 Ltr 190 Ltr
Valve Multi Port Valve of 1.5” Multi Port Valve of 1.5” Multi Port Valve of 1.5”
Back Wash Time 10 to 15 min. 10 to 15 min. 10 to 15 min.
Contents Sand & Pebbles etc. Sand & Pebbles etc. Sand & Pebbles etc.
3)Anthracite Filter
Type Down Flow Down Flow Down Flow
M.O.C. SS FRP FRP
Capacity 190 liters 190 liters 190 liters
Valve Multi Port Valve of 1.5” Multi Port Valve of 1.5” Multi Port Valve of 1.5”
Back Wash Time 10 to 15 min. 10 to 15 min. 10 to 15 min.
Contents Fine Polished Carbons Fine Polished Carbons Fine Polished Carbons
4)Anti Scalene Dosing System
No. Offered One One One
Type Electronics Diaphragm Electronics Diaphragm Electronics Diaphragm
Chemical Anti Scalent Anti Scalent Anti Scalent
Make Of Pump E-Dose E-Dose E-Dose
Make Of Chemical Kimberlite Kimberlite Kimberlite
Solution Tank 50 liters of HDPE 50 liters of HDPE 50 liters of HDPE
5)Micron Cartridge Filter
No. Offered Two Two Two
Type P.P.Spun P.P.Spun P.P.Spun
Make Orange (USA) Orange (USA) Orange (USA)
Micron Size 5&1 micron 5&1 micron 5&1 micron
M.O.C. SS Food Grade FRP Food Grade FRP Food Grade
Size 2” Diameter* 20” Height 2” Diameter* 20” Height 2” Diameter* 20” Height
6)High Pressure Pump
Type Vertical Multi Stage Pump Vertical Multi Stage Pump Vertical Multi Stage Pump
Motor 5 HP 5 HP 5 HP
Make CRI CRI CRI
Flow Rate 5.0m3/h 5.0m3/h 5.0m3/h
7)Reverse Osmosis Unit
Pressure Tube SS FRP FRP
Membrane Hydronautics &CSM-TFC Polymide Hydronautics &CSM-TFC Polymide Hydronautics &CSM-TFC Polymide
Size 4040*16 4040*16 4040*16
Make TFC(USA) TFC(USA) TFC(USA)
8)Instruments
Pressure Gauges 4, 0-21Kgs Of Pressure (Glycerinfill) 4, 0-21Kgs Of Pressure (Glycerinfill) 4, 0-21Kgs Of Pressure (Glycerinfill)
Flow Meters Two on line for product reject Two on line for product reject Two on line for product reject
On-Off Starter Two Two Two
Piping One lot of SS One lot of FRP One lot of FRP
On Line TDS Meter One for Product Water One for Product Water One for Product Water
Panel Board On-Off Starter On-Off Starter On-Off Starter
Meter V- Meter & A- Meter V- Meter & A- Meter V- Meter & A- Meter
Atomization(Optional) Based on water level sensor for raw water product water & anti- scalent chemical Based on water level sensor for raw water product water & anti- scalent chemical Based on water level sensor for raw water product water & anti- scalent chemical